ACCESSORIES

 

VA1DA-x & VA1EH-x Features:

  • Easy installation and replacement (twisted pair connection, useful during switchgear transportation for fast connection)
  • Fault location indication
  • Surface mounting
  • Tube mounting
  • Continuous self-supervision

 

VYX 001: Z-shaped & VYX 002: L-shaped Features:

  • Z, or L shaped brackets
  • Wall mounting to VA1DA-x sensors (no extra holes in the switchgear)

 

Arc-SLmx Features:

  • Length from 1 to 70 meters
  • Self-supervision
  • Cost-effective when lots of compartments are used
  • Activation 8,000 lx
  • Multicore cable
  • 10 mm bending radius minimum

 

Fibre Joint SLS-1 Features:

  • Conveniently connects two fibres together
  • Used for switchgear shipping splits

 

VA1DP-5V Feature:

  • Snap-in socket connection to sensor I/O unit

 

VA1DP-5D Feature:

  • Snap-in socket connection to sensor I/O unit via VX031-5 cable

 

VX031-5 Extension cable Features:

  • Extension cable and door socket for VA1DP-5D
  • Diplexer for two portable sensors

 

Arc Modular Cable VX001-x Feature:

  • Transfers all information and auxiliary supply between VAMP 221 / 321 and I/O units, or between I/O units, easy wiring with RJ 45 connector

 

VAMP 4R Trip Multiplier Relay Features:

  • 4 + 4 trip outputs (4 x NO and 4 x NC)
  • Two separate tripping groups
  • Enables a 7 ms total operation time to a large number of CBs when controlled by arc protection
  • Extended amount of trip contacts for protection systems, trip time 6 ms
  • Auxiliary supply wired from the arc protection main unit

 

VSE 001 External Fibre Optic Module Features:

  • Connects VAMP protection relays and VAMP 321 to a fibre optic loop or a fibre optic star
  • Used with any device which has a RS-232 or TTL serial interface, when a serial fibre optic interface is required
  • Normally available as an optional card, the external module can be used in cases of retrofit if same integrated function is not utilised in the relay

 

VSE 002 External RS-485 Module Features:

  • Connects VAMP protection relays and VAMP 321 to a RS-485 bus
  • Can be used with any device, which has a RS-232 or TTL serial interface, when an RS-485 interface is required
  • Normally available as an optional card, the external module can be used in cases of retrofit if same integrated function is not utilised in the relay

 

VPA 3CG Profibus Adapter Features:

  • VAMP protection relays can be connected to Profibus BP by using an optional Fieldbus card, or via this external device
  • Relay can be monitored from the host system
  • Fieldbus board can be installed inside a VAMP 200 Series relay
  • Normally available as an optional card, the external module can be used in cases of retrofit if same integrated function is not utilised in the relay

 

VARC 931 Arc Flash protection simulator unit:

  • Programming switches in I/O units
  • Example settings for I/O units dipswitches
  • Programming of the V321
  • Trip signals
  • Fault simulation